Heat-Resistant Alloy Steel ASME SA213 High Pressure Boiler Tube for Power Station Boilers Product Description
Product Description: This high pressure boiler tube is made of high-quality heat-resistant alloy steel, strictly complying with ASME SA213 standard, specially designed for power station boilers. It features excellent high-temperature resistance, high pressure-bearing capacity, oxidation resistance and creep resistance, able to withstand the harsh working environment of high temperature, high pressure and continuous operation in power station boiler systems. The tube body is precision manufactured to ensure stable performance, long service life and safe operation, providing reliable support for power station power generation.
Key Parameters: Material: Heat-Resistant Alloy Steel; Standard: ASME SA213; Type: High Pressure Boiler Tube; Length: Various lengths (customizable); Outer Diameter: 10mm-150mm (customizable); Wall Thickness: 2mm-20mm (customizable); Working Temperature: Up to 900℃ (heat-resistant); Working Pressure: High pressure (customizable according to ASME SA213 standard); Surface Treatment: Anti-oxidation coating, pickling passivation; Applicable Scenario: Power Station Boilers.
Application: Widely used in power station boiler systems, including coal-fired power station boilers, gas-fired power station boilers, thermal power boilers, and auxiliary boiler equipment. It is mainly used in boiler heating surfaces, superheaters, reheaters, water walls, downcomers and other key parts that require high heat resistance and high pressure resistance, and can also be applied to industrial high-pressure boilers with similar working conditions.
Product Advantages: High-quality heat-resistant alloy steel ensures excellent high-temperature resistance and creep resistance, avoiding deformation and damage under long-term high-temperature operation; strictly complies with ASME SA213 standard, meets international power station boiler tube quality requirements, with stable mechanical properties; strong high pressure-bearing capacity, able to withstand extreme pressure in power station boiler systems; good oxidation resistance and corrosion resistance, prolonging service life in high-temperature flue gas and water vapor environments; various lengths and customizable sizes fit different power station boiler structural designs.
Product Functions: Transmits high-temperature, high-pressure steam and heat in power station boiler systems, ensuring efficient heat exchange and power generation; withstands long-term high-temperature and high-pressure operation, maintaining structural stability and sealing performance; resists oxidation and corrosion from flue gas and water vapor, reducing maintenance frequency; provides reliable structural support for the safe and stable operation of power station boilers, ensuring continuous power supply.
User Manual: Before installation, carefully check the tube body for scratches, corrosion, cracks, deformation or other defects; clean the inner and outer surfaces of the tube to remove impurities, oxide layers and oil stains; install in accordance with power station boiler installation standards, ensuring accurate alignment and firm connection (welding or flange connection); conduct pressure test, leak test and high-temperature test after installation to confirm compliance with operating requirements; conduct regular inspection and maintenance during use to check for wear, corrosion and deformation.
Precautions: Strictly use within the specified working temperature and pressure range to avoid tube burst or damage; avoid heavy collision, extrusion and scratch during transportation and installation to protect the tube body and surface; store in a dry, ventilated and clean warehouse, away from moisture, high temperature, corrosive substances and mechanical damage; use professional welding and installation personnel to ensure connection quality; regularly check the tube body during operation to prevent hidden dangers.
Delivery Issues: We will arrange delivery within 7-15 working days after receiving the order; delivery methods include sea, air and express, optional according to customer needs (sea transportation is recommended for bulk orders); a tracking number will be provided for you to check the delivery status at any time; for power station boiler tube orders, we will optimize packaging to avoid damage during transportation.
Payment Issues: Acceptable payment methods: T/T, L/C, Western Union, PayPal; Payment terms: 30% advance payment, 70% balance before delivery; For large orders of power station boiler tubes, flexible payment terms can be negotiated to meet customer needs.
Packaging Issues: Packaging: Wooden cases, anti-rust, anti-collision and moisture-proof packaging; Each tube is wrapped with anti-rust film and packed in bundles or wooden cases to prevent scratch, corrosion and deformation; The packaging is sturdy and durable, suitable for long-distance sea transportation and industrial storage, ensuring the tube body remains intact when delivered.